Specification of single air shower

The number of the air blower is the same as that of the single air shower room, and the number of the air blower is installed in the air shower chamber Intelligent circuit board, nozzle, lamp, etc.

Press the emergency stop key for 2 seconds to enter the parameter setting state. At this time, the nixie tube displays SJ, the emergency stop key is used as the setting key, the air shower key is used as the page turning key, and the up and down adjustment keys can adjust the setting parameters. If you press the air shower key, the nixie tube will cycle display Ti, to, TC, Tl, TD, TN 6 parameters in turn. Corresponding to different parameters, press the up and down adjustment key to display the delay time or function status corresponding to the parameter. The system has 4 internal time and 2 function parameter settings: Ti external door unlocking delay setting, to inner door unlocking delay setting, TC air shower delay setting, TL lighting delay setting, TD function setting, TN door exchange setting. After setting, if there is no operation, the system will automatically store and exit the setting state within 5 seconds.

(5) after passing through the primary filter, the air is pressed into the static pressure box by the external rotor fan, and then filtered by the high-efficiency filter, the high-speed clean air flow is blown from the air outlet surface, and the clean air flow is sprayed onto the person with high-speed and uniform wind speed, which can effectively and quickly remove the dust particles attached to clothes / goods.

1. The automatic translation door air shower room and manual door air shower room use power supply of 380v50 Hz, which are three-phase, four wire, automatic door. All the air shower rooms adopt LCD control panel, which is more beautiful and elegant than the traditional LED air shower panel, and has the function of humanized voice prompt system.

We produce the same type of air filter and air shower in multiple production bases around the world. Large scale production capacity ensures that our products can meet the needs of all over the world at any time. Solution to the problem caused by the source of pollutants dust, micro salt particles, air caused microelectronics to fall off or affect the accuracy. The fresh air unit of HVAC system in clean room is added with chemical filtration function section, and chemical filter screen is added in FFU.

The air shower room is the necessary passage for people / goods to enter and leave the clean room, and it also plays the role of airlock in airtight clean room. In order to reduce a large number of dust particles caused by the entry and exit of people / goods, the clean air flow filtered by the high-efficiency filter is sprayed onto the people / goods from all directions by the rotary nozzle, so as to effectively and quickly remove the dust particles. The cleaned dust particles are then filtered by the primary and high-efficiency filters and then recycled to the air shower area.

The air shower channel is a personal purification device used by operators when entering the clean room. It uses high-speed clean air to blow and drench away the dirt from the people entering the room. The nozzle can be adjusted to effectively remove dust from the body and prevent external pollution from entering the clean area. It can also be used for large goods.

1. Air shower time setting: This is the external time parameter option. Before or after the start and end of air shower, the delay time of air shower can be changed by continuously pressing the down adjustment button of upper and single person double air dryer for 3 seconds. The adjustment range is 1-99 seconds, and it is displayed by double digit digital tube. After 5 seconds of adjustment, the system will automatically save the parameter value.

The service life of the air shower room is also the issue that many manufacturers should refer to when purchasing, and the service time is also?

In the production of automobile and aviation industry, if 10um dust mixed into the paint layer, the defects caused by dust can be seen by human eyes. In order to ensure the paint quality of the car surface, a large number of air filters are used in the painting workshop (paint shop) of automobile manufacturers to remove the dust in the air of painting and baking production lines.

(3) all stainless steel door, door frame, handle, thickened floor plate and air shower nozzle are used as basic configuration.

2. Manual door the air shower room usually has a single door. When the induction zone receives the command, the door in one direction can be opened manually.

After the production or installation of the air shower room, the manufacturer or the owner of the air shower room shall carry out the basic test. The single air shower room is used to determine whether the air shower room is qualified or not. The following several important testing standards sorted out by Jinyi purification air shower manufacturer can be used for reference?

The distance between the head and the disk is very small, generally only one hundred thousandth of a centimeter, which is smaller than dust. Therefore, the production of hard disk must be carried out under the condition of super dust. The clean room of hard disk manufacturer is between class 100 and even grade 10, and the diameter is greater than 0. No more than 100 particles of 5 μ m are larger than 0. No more than 300 3 microns.

A small amount of untreated particles or gas molecules may seriously affect some process flow. Imagine the possible harm of polluted air to semiconductors and other highly sensitive manufacturing processes. Advanced production methods usually require a very clean air environment, and in many cases, air requirements may be more stringent.

(1) adopt the clean principle of international standard and the cabinet design. Double door electronic interlock, infrared induction automatic shower, double door locking during shower.

In order to achieve the effect of shower, the wind speed at the nozzle outlet of the air / cargo shower room can reach more than 25m / s, the wind speed blowing to the person is * * 18m / s, and the factory initial air shower time is set to 15 seconds.

Many large enterprises regard the company as a long-term partner, and the company also has the ability to meet a variety of air filtration needs worldwide. We have been investing heavily in R & D centers around the world, specializing in R & D products to meet the needs of the industry. We always adhere to close cooperation with customers to meet or exceed their expectations for air filtration products.

  1。 Leakage detection of high-efficiency filter. After the installation of high-efficiency filter, the leakage detection shall be carried out according to the site leakage detection method provided in the code for construction and acceptance of clean room.